Background and Aims: The Air-Q blocker (Cook gas LLC, Mercury Medical, Clearwater, FL, USA) is a relatively new supraglottic airway device (SAD) with capability to serve as a conduit for intubation. As there is limited data on Air-Q blocker, the present study was performed to compare the efficacy of Air-Q blocker and Proseal laryngeal mask airway (PLMA) in patients undergoing elective surgery. Methods: A total of 90 American Society of Anesthesiologists (ASA) physical status I and II patients were randomly allocated to Air-Q blocker or PLMA group. Oropharyngeal leak pressure (OLP), insertion success, insertion time, ease of orogastric tube (OGT) insertion, fibreoptic visualisation of the glottis, haemodynamic and ventilation parameters, and complications at emergence and postoperatively were investigated. Results: OLPs were higher in PLMA group as compared to Air-Q blocker group (P = 0.002). Still, the OLP (27.5 ± 5.8 cm H2O) was clinically effective in Air-Q blocker group.The mean time for successful insertion was significantly shorter for Air-Q blocker than PLMA (P = 0.019). The number of attempts to insert both the devices was comparable (P ≥ 0.05). Air-Q blocker provided a significantly better fibreoptic score than PLMA (P = 0.038). The two groups were comparable in terms of ease of OGT insertion, haemodynamics and ventilation parameters, and complications at emergence and postoperatively. Conclusions: Air-Q blocker provides a clinically effective OLP though PLMA provides a slightly better sealing function in patients undergoing laparoscopic and non-laparoscopic surgeries under general anaesthesia requiring neuromuscular blockade. Air-Q blocker has shorter insertion time and a better fibreoptic view of glottis as compared to PLMA.


How to cite this article:
Jindal S, Mittal A, Anand LK, Singh M, Kapoor D. Comparative evaluation of Air-Q blocker and Proseal laryngeal mask airway in patients undergoing elective surgery under general anaesthesia: A randomised controlled trial.Indian J Anaesth 2021;65:20-26


How to cite this URL:
Jindal S, Mittal A, Anand LK, Singh M, Kapoor D. Comparative evaluation of Air-Q blocker and Proseal laryngeal mask airway in patients undergoing elective surgery under general anaesthesia: A randomised controlled trial. Indian J Anaesth [serial online] 2021 [cited 2021 Apr 14 ];65:20-26
Available from: https://www.ijaweb.org/article.asp?issn=0019-5049;year=2021;volume=65;issue=13;spage=20;epage=26;aulast=Jindal;type=0