• Users Online: 570
  • Print this page
  • Email this page


 
 Table of Contents    
LETTERS TO EDITOR
Year : 2021  |  Volume : 65  |  Issue : 2  |  Page : 173-174  

External jugular vein cannulation – A double-edged sword


1 Department of Anaesthesiology and Critical Care, All India Institute of Medical Sciences, Bhubaneswar, Odisha, India
2 Department of Trauma and Emergency, All India Institute of Medical Sciences, Bhubaneswar, Odisha, India

Date of Submission26-May-2020
Date of Decision18-Jun-2020
Date of Acceptance14-Jul-2020
Date of Web Publication10-Feb-2021

Correspondence Address:
Chitta Ranjan Mohanty
Department of Trauma and Emergency, All India Institute of Medical Sciences, Bhubaneswar - 751 019, Odisha
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/ija.IJA_672_20

Rights and Permissions

How to cite this article:
Ahmad SR, Bellapukonda S, Mohanty CR, Tapuria P. External jugular vein cannulation – A double-edged sword. Indian J Anaesth 2021;65:173-4

How to cite this URL:
Ahmad SR, Bellapukonda S, Mohanty CR, Tapuria P. External jugular vein cannulation – A double-edged sword. Indian J Anaesth [serial online] 2021 [cited 2021 Mar 9];65:173-4. Available from: https://www.ijaweb.org/text.asp?2021/65/2/173/309104



Sir,

External jugular vein (EJV) cannulation is an indispensable armour in establishing quick venous access to the central compartment. In the current scenario of the coronavirus disease (COVID)-19 pandemic, its use is even more crucial as the insertion of central venous catheter (CVC) is difficult with personal protective equipment due to logistic issues (fogging and restriction of movement).[1] In addition to serving all the purposes of the CVC, EJV is easy to cannulate because of its constant anatomy. Hence, it is widely used in the intensive care unit, operation theatre and emergency department. The learning curve and time taken for EJV cannulation is less when compared to CVC and needs less expertise. Its superficial location away from major neurovascular bundles makes it safe for cannulation.[2] The role of a wide bore EJV cannula cannot be overemphasised for rapid resuscitation with no peripheral intravenous access. Peripheral veins collapse in hypovolemic patients in shock due to the shift of blood to the central compartment. EJV serves as a route for infusion of fluids, blood, hyperosmolar/vesicant drugs and inotropes/vasopressors. EJV is an alternative to the CVC in patients with coagulopathy with the unavailability of ultrasonography (USG). It also has fewer chances of pneumothorax and arterial punctures. Moreover, it can be used as a channel for CVC insertion with USG confirmation.[3]

Although there are several advantages to securing EJV, it is not without its share of complications. To state a few are, EJV being continuous with the central compartment, its cannulation and removal can lead to air embolism.[4] In patients with a cervical spine injury, positioning the neck for EJV placement can lead to further neurological damage. It has been reported that idiopathic EJV thrombosis can follow in patients with cervical trauma, infection and neck malignancies.[5] In these cases, cannulation can lead to thrombus dislodgement and cannula migration leading to embolism.[6] In head-and-neck surgeries, extreme rotation of the neck (park bench, dead lateral or prone position with full neck flexion) may block EJV intraoperatively. The presence of tracheostomy or cervical collar hinders its placement and access.

Furthermore, a few nuances are to use a good quality catheter, and USG during the removal of this cannula and this may help to avoid catheter breakage, migration and easy detection.[7] It is a potential source for infection and should be cared as CVC care bundles. Attaching a three-way extension [Figure 1] would avoid contamination of cannula and air embolism. Early removal of the catheter, at around 3 days or when not needed, prevents infection.
Figure 1: Attachment of a three-way extension to external jugular vein cannula, which would avoid contamination of cannula and air embolism

Click here to view


Thus, EJV cannulation seems to be a minor procedure and gadget. In the current scenario of the COVID-19 pandemic, it is invaluable due to the technical difficulties in establishing central venous access. Careful use can surmount its complications. Adherence to strict asepsis and care bundle, along with the merits of EJV might thus outshine.

Financial support and sponsorship

Nil.

Conflicts of interest

There are no conflicts of interest.



 
   References Top

1.
Malhotra N, Bajwa SJ, Joshi M, Mehdiratta L, Trikha A. COVID operation theatre-advisory and position statement of indian society of anaesthesiologists (ISA National). Indian J Anaesth 2020;64:355-62.  Back to cited text no. 1
  [Full text]  
2.
Chakravarthy M, Krishnamoorthy J, Nallam S, Kolur N, Faris A, Reddy K, et al. External jugular venous route for central venous access: Our experience in 563 surgical patients. J Anesth Clin Res 2011;2:144.  Back to cited text no. 2
    
3.
Magoon R, Malhotra SK, Saini V, Sharma R, Kaur J. Randomised controlled trial of central venous catheterisation through external jugular vein: A comparison of success with or without body manoeuvres. Indian J Anaesth 2017;61:985-9.  Back to cited text no. 3
    
4.
Mohanty CR, Ahmad SR, Jain M, Sriramka B. Air embolism through open hub of external jugular vein intravenous cannula. Turk J Emerg Med 2019;19:117-9.  Back to cited text no. 4
    
5.
Villanueva CT, Ruiz JR. Idiopathic external jugular vein thrombosis. Eur J Case Rep Intern Med 2019;6:001058.  Back to cited text no. 5
    
6.
Mohanty CR, Panda R. Fracture and embolization of intravenous cannula placed in external jugular vein: A rare complication. Saudi J Anaesth 2018;12:504-5.  Back to cited text no. 6
    
7.
Mohanty CR, Ahmad SR, Elyat A, Bellapukonda S, Panigrahi SK. Point-of-care ultrasonography: A boon for early localization and retrieval of broken fragment of external jugular venous catheter. Korean J Anesthesiol 2020;73:77-8.  Back to cited text no. 7
    


    Figures

  [Figure 1]



 

Top
 
  Search
 
    Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
    Access Statistics
    Email Alert *
    Add to My List *
* Registration required (free)  

 
  In this article
    References
    Article Figures

 Article Access Statistics
    Viewed493    
    Printed0    
    Emailed0    
    PDF Downloaded118    
    Comments [Add]    

Recommend this journal