Year : 2021  |  Volume : 65  |  Issue : 2  |  Page : 162-163  

A convenient assembly for drug dilution


Department of Anaesthesiology and Critical Care, All India Institute of Medical Sciences, Jodhpur, Rajasthan, India

Date of Submission03-Jun-2020
Date of Decision29-Jun-2020
Date of Acceptance14-Jul-2020
Date of Web Publication10-Feb-2021

Correspondence Address:
Bharat Paliwal
G-80, Parsvnath City, Jodhpur - 342 013, Rajasthan
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/ija.IJA_724_20

Rights and Permissions

How to cite this article:
Paliwal B, Kamal M, Roy S, Kumari K. A convenient assembly for drug dilution. Indian J Anaesth 2021;65:162-3

How to cite this URL:
Paliwal B, Kamal M, Roy S, Kumari K. A convenient assembly for drug dilution. Indian J Anaesth [serial online] 2021 [cited 2021 Feb 27];65:162-3. Available from: https://www.ijaweb.org/text.asp?2021/65/2/162/309107



Sir,

Use of normal saline for dilution of drugs is a common practice, especially for paediatric patients and for inotropic medications. 5-mL and 10-mL normal saline (NS) ampoules are available in the market for this purpose. However, due to lack of availability of such NS ampoules at many centres, varied practices have been observed. Few use a commercially available prefilled 'flush' syringe to dilute medications.[1],[2] More commonly, 100-mL or 500-mL NS bottles are used for dilution. Several methods are adopted to draw saline from these bottles. One of the common methods is introduction of wide-bore needle on the top of the container for repeated aspirations. The hub of the needle is closed by an intravenous cannula stopper after withdrawal of NS for subsequent use. Few others have incorrect practice of cutting near-completely the top portion of the bottle in a semi-circular manner using a surgical blade, which is replaced in between aspirations. Still, some others dedicate a saline bottle for diluting drugs and prick it with the needle of a syringe each time they need fluid from it. These methods cannot guarantee sterility of saline and cannot prevent entrainment of atmospheric air into the bottle. Moreover, in these processes, the NS gets spilled occasionally. Furthermore, the use of flush syringes for dilution may be a potential source of drug error.[3],[4] In cardiac operation theatre and intensive care unit, we are using 500-mL self-collapsible NS pouches which are punctured at dedicated site of fluid withdrawal with an 18G needle attached with a 3-way adaptor [Figure 1]a. The 3-way adapter is turned on for aspiration after a sterile syringe is connected to it, closed before syringe disconnection and capped [Figure 1]b. This practice minimises entrainment of external air and chances of contamination of NS pouch. It also obviates the need of using multiple small NS ampoules for large dilutions that might be time-consuming, need extra workforce and are expensive too. It thus, eases the practice, especially when an anaesthetist is devoid of technical assistance and he/she has to be multitasking. Similar assembly may be used with 100-mL saline pouches. Although the method may not be at par with safe practices, it may be better than prevailing practices in resource-limited settings.[5]
Figure 1: (a) Needle and 3-way assembly. (b) Self-collapsing fluid pouch with needle and 3-way assembly

Click here to view


Financial support and sponsorship

Nil.

Conflicts of interest

There are no conflicts of interest.



 
   References Top

1.
Institute for Safe Medication Practices. Some IV medications are diluted unnecessarily in patient areas, creating undue risk. ISMP Med Safety Alert 2014;19:1-5. Available from: https://www.ismp.org/resources/some-iv-medications-are-diluted-unnecessarily-patient-care-areas-creating-undue-risk. [Last accessed on 2020 Jul 09].  Back to cited text no. 1
    
2.
Arya VK. Basics of fluid and blood transfusion therapy in paediatric surgical patients. Indian J Anaesth 2012;56:454-62.  Back to cited text no. 2
[PUBMED]  [Full text]  
3.
Velayudhan S, Arumugam V. Syringe label: A potential source of dosage error. Indian J Anaesth 2014;58:506-7.  Back to cited text no. 3
[PUBMED]  [Full text]  
4.
Juwarkar C, Ghoshal P, John A. Mishap due to error in labelling-word of caution! Indian J Anaesth 2014;58:369-70.  Back to cited text no. 4
    
5.
Institute for Safe Medication Practices (ISMP). ISMP Safe Practice Guidelines for Adult IV Push Medications; 2015. p. 1-24. Available from: https://www.ismp.org/sites/default/files/attachments/2017-11/ISMP97-Guidelines-071415-3.%20FINAL.pdfs. [Last accessed on 2020 Jul 09].  Back to cited text no. 5
    


    Figures

  [Figure 1]



 

Top
 
  Search
 
    Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
    Access Statistics
    Email Alert *
    Add to My List *
* Registration required (free)  

 
  In this article
    References
    Article Figures

 Article Access Statistics
    Viewed325    
    Printed0    
    Emailed0    
    PDF Downloaded59    
    Comments [Add]    

Recommend this journal