LETTER TO EDITOR
Year : 2010  |  Volume : 54  |  Issue : 2  |  Page : 175-176 Table of Contents     

Water in a nitrous oxide flowmeter


Postgraduate Institute of Medical Education and Research, Chandigarh - 160 012, India

Date of Web Publication24-May-2010

Correspondence Address:
Virendra K Arya
Department of Anesthesia and Intensive Care, PGIMER, Chandigarh - 160 012
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/0019-5049.63633

Rights and Permissions

How to cite this article:
Arya VK, Arora V. Water in a nitrous oxide flowmeter. Indian J Anaesth 2010;54:175-6

How to cite this URL:
Arya VK, Arora V. Water in a nitrous oxide flowmeter. Indian J Anaesth [serial online] 2010 [cited 2020 Nov 29];54:175-6. Available from: https://www.ijaweb.org/text.asp?2010/54/2/175/63633

Sir,

We are reporting a rare but critical incident wherein water was detected in a nitrous oxide (N 2 O) flowmeter. This incident occurred in the gynecology OR where the anaesthesiologist used an O 2 / N 2 O mixture with a volatile agent for maintenance of anaesthesia. After about one to two minutes of opening the N 2 O flowmeter control valve, a spurt of yellowish colored fluid from the needle valve filled the flowmeter barrel and the bobbin jumped erratically up and down on it. The fluid got accumulated over the bobbin making it stick to the side of the barrel and cease its rotations [Figure 1]. The total flow of the gas from the common gas outlet also decreased, as evidenced by the empty feel of the ventilating reservoir bag. The N 2 O was immediately shut off and patient was maintained on 100% O 2 from the cylinder supply, while ventilating with a self-inflating resuscitation bag. Fortunately, the fluid did not travel distally into the breathing system. On disconnection of the N 2 O hose from the terminal unit and connecting yoke, some water was found emerging from the yoke adapter [Figure 2]. On purging the terminal units no contamination of gases with any fluid was observed. No problem was encountered after using new hoses and a new anaesthesia machine.

Subsequent investigation revealed that on the previous day gas hoses of the same OR were disconnected for maintenance. Subsequently, only the O 2 hose was connected by the maintenance staff and the N 2 O hose remained disconnected from the terminal unit overnight. It was possible that the water vapour entering from the atmosphere could have condensed under pressure on reconnection in the morning. A routine morning check of the machine did not reveal any problem due to the small quantity of water, which took some time to reach up to the flowmeter. A similar incident had been reported earlier, where a central air pipeline was found contaminated by water condensation, as it was kept open to atmosphere during maintenance. [1] We feel that purging of hoses must be done with central pipeline dry gases before connecting the yoke adapter to the machine for prevention of this problem. In addition to patient safety concerns, any water in the gas supply would also lead to malfunction of vaporisers and a major break down in the modern anaesthesia machines with electronic components.

 
   References Top

1.Hay H. Contamination of piped medical gas supply with water. Eur J Anaesthesiol 2000;17:512-4.  Back to cited text no. 1      


    Figures

  [Figure 1], [Figure 2]


This article has been cited by
1 Water in the Flowmeters
Lakesh K. Anand,Dheeraj Kapoor,Sunita Kazal
Anesthesia & Analgesia. 2013; 117(1): 281
[Pubmed] | [DOI]



 

Top
 
  Search
 
    Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
    Access Statistics
    Email Alert *
    Add to My List *
* Registration required (free)  

 
  In this article
    References
    Article Figures

 Article Access Statistics
    Viewed1304    
    Printed62    
    Emailed0    
    PDF Downloaded276    
    Comments [Add]    
    Cited by others 1    

Recommend this journal